Silver SHD Series Electromagnetic Flow meter is perfect to measure conductive liquid, grout and slurry.This Flow meter is accurate measuring, no pressure loss and no moving or extruding parts, wear and corrosive resistance, can be installed in any pipelines.This kind of flow instruments can be used in Chemical, Pharmacy and cosmetic fields, Municipal water supply, sewage plant, food and paper factory.
Electromagnetic Flow meters Transmit and measure the flow, volumetric flow of conductive liquid, slurry.,ect.
Electromagnetic Flow meter measuring system consists of a converter and a mag flow sensor, flow sensor is installed in the required pipeline, while converter can be installed in the field or other place (that is remote Version).If it is compact design, sensor and converter integrally constructed.
Sensor and Converter
Compact Type Magnetic Flow meter |
Remote Type Magnetic Flow meter |
|
|
Environment temperature:-25°C~ + 60°C;
Relative Humility: 5% ~90%
Power supply: 85VAC~250VAC; 16VDC~36VDC
Consumed power: less than 20W
Standard SHD-SE11/ Sanitary SE13:±0.5%;High Accuracy SE12 series Mag meter :±0.25% Inserted type SE 14 type mag meter :±1.5%
Flow meter Measuring Error
Load Resistance: 0mA~10mA, 0 k Ω~1.5 K Ω
Load Resistance: 4mA~20mA, 0 k Ω~750 Ω
Intrinsic Error: o.1&%±10μA
Frequency Output Range: 1 Hz ~ 5000 Hz
Output Electrical Isolation: Optoelectronic Isolation, Isolation Voltage: > 1000VDC
Frequency Output Driver: Field-Effect Tube Output, Max bearing Voltage 36VDC, Max load Current 250mA
Output Pulse Range: 0 pulse/second ~ 100 pulses /second. (Higher than 100 pulses/second, pulse can be lost)
Scaled Output Pulse: 0.001 m3/cp~1.000 m3/cp; 0.001 LTR/cp ~1.000 LRT/cp
Output Electrical Isolation: Optoelectronic Isolation, Isolation Voltage: > 1000VDC
Frequency Output Driver: Field-Effect Tube Output, Max bearing Voltage 36VDC, Max load Current 250mA
Alarm Output Point: ALH –Upper limit Alarm, ALML—lower limit Alarm
Output Electrical Isolation: Optoelectronic Isolation, Isolation Voltage: > 1000VDC
Frequency Output Driver: Field-Effect Tube Output, Max bearing Voltage 36VDC, Max load Current 250mA
MODBUS Interface: RTU Format, Physical Interface RS-485, Electrical Isolation 1000VH
Hart Protocol Interface: Standard Hart Protocol configures HART Communicator, can display the measuring flow valve on line and modify the flow instruments technical parameters.
Forbidden: