Vortex Flow meter is for clean liquid, gas and steam flow measurement. Contact us to choose proper type flow sensor and ...
Buy Quality Electromagnetic Flow meter from China manufacture in low price and fast delivery time. Get the Mag meter Pri...
Description |
Specifications |
|||
Input Signal |
Analog Input |
Pulse Input |
||
Thermocouple: K, E, B, J, N, T, S |
Waveform: Rectangular, Sine and Triangle wave |
|||
Pt100 |
Amplitude: more than 4V |
|||
Current: 0-10mA, 4~20mA Input impedance≤250Ω |
Frequency: 0~10KHz Special requirements please contact us |
|||
Output Signal |
Analog Output |
Communication Output |
Switch Output |
Feed Output |
DC 0~10mA(load resistance≤750Ω) |
RS232, RS485, Ethernet |
Relay with hysteresis |
DC24V (load current≤100mA) |
|
DC 4~20mA (load resistance≤500Ω) |
Baud rate: 600, 1200, 2400, 4800, 9600bps,8 data bits, 1stop bit, and 1 start bit |
AC220V/3A; DC24V/6A(Resistive load) |
DC12V (load current≤200mA) |
|
Accuracy |
0.2%FS±1d or 0.5%FS±1d Accuracy for frequency conversion: ±1 pulse (LMS), better than 0.2% |
|||
Measuring Range |
-999999~999999 for flow rate and compensation value 0~99999999.9999 for totalizer |
|||
Display |
Backlit 128*64 lattice LCD Display flow totalizer, flow rate, energy, power, medium temperature, medium pressure, medium density, medium heat enthalpy, differential pressure, current, frequency, date, time, Alarm status |
|||
Control/ Alarm |
Optional relay upper limit and lower limit control (Alarm) output, LCD and LED output indication; Control (Alarm) with hysteresis (The number of alarm relay is up to 2) Alarm type: flow upper and lower limit, temperature upper and lower limit, pressure upper and lower limit; |
|||
|
Through RS232 interface to Serial thermal printer Real-time print or timing print, Up to 8 times timing print in one day. |
|||
Protection |
Totalizer will be remained for more than 20 years after power off Reset automatically when Power supply is low Reset automatically when abnormal working (Watch Dog) Self-healing fuse Short circuit protection |
|||
Password protection for important data |
||||
Operating environment |
Ambient temperature : -20~60℃; Relative humidity: ≤85%RH, Far from strong corrosive gas |
|||
Power supply |
Normal Type: AC 220V % (50Hz±2Hz) Special Type: AC 80~265V (Switch power) DC 24V±1V (Switch power) (AC 36V 50Hz±2Hz) Back-up power: +12V, 20AH, it will last 72 hours |
|||
Power consumption |
≤10W |
AJ Flow Meter Totalizer Display Screen
Sample 1
DN50 Vortex flow sensor, measure vapor; average flow coefficient is 9.4132/l; temperature and pressure compensation; temperature sensor Pt100; pressure transmitter 0-1,6MPa; 4-20mA output; No alarm; low frequency cut-off is 60Hz; temperature range +150~200℃ (If temperature is out if the range, use 180℃ setting temperature); pressure range 0.7~1.0MPa (If pressure is out if the range, use 0.8MPa setting pressure).
Parameter Configuration of flow totalizer
Sample 2
V-cone flowmeter, measure vapor mass; Rosemount 3051 differential pressure transmitter, Pt100 and pressure transmitter; differential pressure transmitter range 0 ~ +300Pa; output 4-20mA No ; flow range 20t/h; design density 3.3342kg/m3;pressure transmitter range 0 ~ 1.6MPa; temperature range +170~+260℃; common temperature: +200℃; pressure range 0.6~1.0MPa; common pressure: +0.7MPa; low current cut-off 4.005mA.
Parameter Configuration of flow totalizer
Sample 3
Magnetic flowmeter, measure liquid; output 4-20mA; range 0-60m3/h.
Parameter Configuration of flow totalizer
Item |
Code |
Description |
General |
AJ |
AJ series Flowmeter Totalizer |
Dimension |
8 |
160×80mm (horizontal) |
Communication |
00 |
No communication function |
01 |
RS-485 communication |
|
02 |
RS-232 communication |
|
03 |
Ethernet (English is unavailable) |
|
Alarm 1 |
1NO |
Switching signal of relay output |
2NC |
||
Alarm 2 |
1NO |
|
2NC |
||
Output |
1 |
Current Output |
2 |
Pulse output |
|
Input |
1 |
Thermocouple |
2 |
Pt100 |
|
3 |
Pt1000 |
|
4 |
Current: 0-10mA |
|
5 |
Current: 4-20mA |
|
Feed Output |
1 |
DC +5V |
2 |
DC +12V |
|
3 |
DC +24V |
|
Power Supply |
1 |
AC 220V |
2 |
AC 36V |
|
3 |
DC 24V |
|
Extended Function |
1 |
USB interface, using to download the data in meter |
2 |
Current: 4-20mA |
|
3 |
16 Bit A/D convertor module |
|
4 |
Wireless remote control function.*1 |
*1 Mainly used in dangerous occasion and condition of no opening the flow totalizer.