EMF flow meter for 10% KOH Solution and NH4OH Solution (7-9 pH Value)
Specifications
Excitation
 :
 Pulsed DC
Material of Construction:
 Metering tube, flange and electrodes in SS304 L/ SS316. PTFE Liner.
Display LCD
 :
 Digital display 4 digits for flow rate & 8 digits for totalizer. (Averaging of display for oscillating flow  can be present)
Alarm
 :
 High and Low alarm set points with contactors, 1 AMP Settable Over Entire Range: Empty pipeline indication can be available.
Accuracy
 :
 +/- 0.5% of FS
Stability
 :
 +/- 0.25% FS for 1 year.
Repeatability
 :
 +/- 0.25% FS for 1 year.
Linearity
 :
 +/- 0.5% of FS
Output
 :
 4~20mA DC Isolated output to drive at least 600 ohms load
Electromangetic flow meter with HART
 :
 HART Communication optional.
Power Supply
 :
  24 V DC
Memory Back Up
 :
 Non Volatile memory / Battery backup for retaining programmed data.
Protection Class
 :
 IP65. Housing epoxy coating Alkali resistant.
Pressure rating
 :
 Maximum pressure rating shall be 10 kg/cm2
Duty
 :
 For continuously operating plant 
Magnetic flow meter size avaiable: DN10 to DN2000, normally request 1" size mag meter or 2" mag meter
Accessories
 :
 1) Reducer or expander if required can be provided by the supplier.
 2) Grounding ring/Electrode can be provided. 