China thermal mass flow meter with cheap price. Gas flow meter for compressed air flow meter,biogas flow meter ,LPG flow...
Vortex Flow meter is for clean liquid, gas and steam flow measurement. Contact us to choose proper type flow sensor and ...
SGW gas turbine flow meter which assimilates the advanced turbine technology of flow meters digital for gas from China and overseas with optimum design, is a new generation of gas flow meter with high precision and reliability based on the theory of pneumatics, hydromechanics ,electro-magnetic etc. Turbine gas flow meter has excellent performance under both low and high pressure , various ways of signal output and low sensitivity to the fluid turbulence,. Thus gas turbine meter is widely applied to the measurement of gas flow, such as used as natural gas flow meter, n2 flow meter (Nitrogen flowmeter ) ,biogas flow meter, LPG gas flow meter or industrial air flow sensor. SILVER AUTOMATION INSTRUMENTS is reliable gas turbine flow meter China manufacturer.
Medium |
Clean gas with low to medium velocity,used such as biogas flow meter,LPG gas flow meter,nitrogen gas flow sensor. |
||||
Standard |
Gas measurement in closed pipe-Turbine flow sensor(GB/T18940-2003) |
||||
Gas flow meter Size & connection |
Flange type |
Stainless steel housing |
DN25-DN300 |
||
Aluminum housing |
DN25,50,80,100 |
||||
Carbon steel |
DN350,400 |
||||
Thread type |
Stainless steel(non compensation) |
DN25,40,50 |
|||
Stainless steel(compensation) |
DN25, 40, |
||||
Flange |
Standard |
GB/T9113.1-2000 |
|||
Others |
DIN,ANSI,JIS |
||||
Thread |
Standard |
BSPP(male) |
|||
Others |
BSPP(Female),NPT.,etc. |
||||
Accuracy & Repeatability |
Accuracy |
±1.5%R |
±1.0%R(Option) |
||
Repeatability |
≤0.5% |
≤0.15% |
|||
Turn down ratio |
30:1-10:1 |
||||
Gas meter Calibration |
Facility |
1. Master Meter calibrationfacility 2. Sonic nozzle gas flow calibrationfacility 3. Bell prover gas calibration facility |
|||
Environment |
Temperature: 20℃ |
||||
Relative Humidity: 75% |
|||||
Working Condition |
Medium temperature: -20 ~80℃ Atmospheric pressure: 86Kpa-106Kpa Environmenttemperature:-20 ~60℃ Relative Humidity5%-90% |
||||
Typical Error Curve |
|
Size-Flow-Flow rate
|
|
Standard Flow Range |
Extended Flow Range |
Size (mm) |
Standard (m3/h) |
Extended (m3/h) |
Standard Pressure |
Special Pressure |
||
DN20 |
S |
2-20 |
W |
4-40 |
1.6Mpa |
Thread≤4.0Mpa,Flange≤6.3Mpa |
DN25 |
S |
2.5-25 |
W |
4-40 |
Thread≤4.0Mpa,Flange≤6.3Mpa |
|
DN32 |
S |
4-40 |
W |
6-60 |
Thread≤4.0Mpa,Flange≤6.3Mpa |
|
DN40 |
S |
5-50 |
W |
6-60 |
Thread≤4.0Mpa,Flange≤6.3Mpa |
|
DN50 |
S1 |
6-65 |
W1 |
5-70 |
Thread≤4.0Mpa,Flange≤6.3Mpa |
|
S2 |
10-100 |
W2 |
8-100 |
|||
DN65 |
S |
15-200 |
W |
10-200 |
Flange≤6.3Mpa |
|
DN80 |
S1 |
13-250 |
W |
10-160 |
Flange≤6.3Mpa |
|
S2 |
20-400 |
|||||
DN100 |
S1 |
20-400 |
W |
13-250 |
Flange≤6.3Mpa |
|
S2 |
32-650 |
|||||
DN125 |
S |
25-700 |
W |
20-800 |
Flange≤6.3Mpa |
|
DN150 |
S1 |
32-650 |
W |
80-1600 |
Flange≤6.3Mpa |
|
S2 |
50-1000 |
|||||
DN200 |
S1 |
80-1600 |
W |
50-1000 |
Flange≤4.0Mpa |
|
S2 |
130-2500 |
|||||
DN250 |
S1 |
130-2500 |
W |
80-1600 |
Flange≤2.5Mpa |
|
S2 |
200-4000 |
|||||
DN300 |
S |
200-4000 |
W1 |
130-2500 |
Flange≤2.5Mpa |
|
W2 |
320-6500 |
|||||
DN350 |
S |
400-8000 |
W1 |
150-4500 |
-------- |
|
W2 |
300-9000 |
|||||
DN400 |
S |
500-10000 |
W1 |
300-9000 |
-------- |
|
W2 |
500-10000 |
Model |
SGW-N |
SGW-A |
SGW-B |
SGW-C |
SGW-D |
Picture |
|
|
|
||
Display |
No Digital Display No temperature and pressure compensation |
Digital Display Instant & Totalized Flow No temperature andpressure compensation |
Digital Display Instant & Totalized Flow Temperature and pressure compensation |
||
Diameter |
DN20-DN400 |
||||
Output |
Pulse |
4-20mA |
No |
4-20mA/Pulse |
4-20mA/Pulse |
Power |
24VDC±15% |
Battery*1 |
24VDC±15% |
24VDC±15% & Battery |
|
Flow Range |
Standard |
Standard or Extended Flow range |
|||
RS485 |
No |
RS485 Option |
|||
Power consumption< 0.5W |
|||||
Protection level: IP65 |
*1 Battery life of gas flow meter is around 56 months
Item | Code | Description |
General | SGW | Silver Gas turbine flow meter |
Type | N | Without display, pulse output, 24VDC power supply |
A | Without display ,4-20mA output, 24VDC power supply | |
B | With display, Battery powered, without output | |
C | With display,4-20mA output, 24VDC power supply | |
C3 | With display, pulse output, 24VDC power supply | |
C1 | With display, 4-20mA output,RS485,24V DC power supply | |
D | Display, temperature and pressure compensation,4-20mA | |
D1 | Display, T& P compensation,4-20mA,RS485 | |
NominalDiameter | 20-400 | DN20-DN400 |
Flow range | W(x) | Refer to table 2 |
S(x) | Refer to table 2 | |
Turbine Sensor Material | S | Stainless steel housing(DN25-DN300) |
L | Aluminum housing(DN25,50,80,100) | |
C | Carbon steel(DN350,DN400) | |
Rotar, bearing Material | S | Corrosion Resistance ABS |
L | Aluminium-Alloy | |
Structure | N | Standard Structure |
A | For Oxygen Only (O2 Only) | |
Accuracy | 10 | ±1.0% of reading |
15 | ±1.5% of reading | |
Explosion Proof | N | Non explosion proof |
E | ExdIIBT6 | |
Pressure Rating | N | Standard, (refer to table2) |
H(x) | Customized,(refer to table2) | |
Installation | FL | Flange connection |
LW | Thread Connection *1 |
*1 Specify Turbine meter Thread standard when ordering, thread connection available on DN20-DN50 turbine flow meter .
Welcome to send inquiry to us for SGW Gas Turbine Flow meter Price.