Chemical flow meters are intended to measure non-corrosive or corrosive liquid and gas, for example pesticides, detergen...
Why Nitric acid level measurement is a tough job? Nitric acid (HNO3) is a strong acid with strong oxidizing and corrosiv...
1/2 inch turbine flow sensor, DN15, standard flow 10-100 LPM or 400-8000 LPH3/4inch corrosive liquid flow meter, NB20, standard flow 3.5-35 gpm, or 16-318 ft3/h1” chemical resistant flow meter, DN25,1-10 m3/h or 8.3-166 L/min1 1/4” TUF flow meter , DN32, flow range: 0.4-4 m3/h or 3.5 -66 GPM1 1/2 inch turbine flow sensor, DN40, 2-20 m3/h or 1-20 m3/h2” turbine flow meter , DN50, flow range 17-176 GPM, 33-333 m3/h2 1/2 turbine flow transmitter, NB65, flow range 1.94 ~19 .4L/s or 141 -2472 ft3/h
Manufacture Standard |
Turbine flow meter (JB/T9246-1999) |
|
Medium |
Low viscosity(≤5×10-6m2/ s) liquid, no impurities |
|
Flange Standard |
DIN |
|
Thread Standard |
Flange |
|
Accuracy |
1.0%,0.5% |
|
Turn Down Ratio |
1:10-1:20 |
|
Calibration |
Methods |
Master meter calibration |
Static weigh mass flow calibration |
||
Environment |
Environment temperature: 20℃ |
|
Relative Humidity :65% |
||
Working Condition |
Medium temperature |
T1: -20 ~80℃ |
Environment temperature |
-20 ~60℃ |
|
Relative Humidity |
5%-90% |
|
Atmospheric pressure |
86Kpa-106Kpa |
|
Enclosure Protection |
SLW-N:IP60; others IP65 |
|
Transmission Distance |
No more than 1000 m |
|
Material |
Housing: PE Bearings and Shaft: PE Rotor:PE |
|
Consumption |
< 1W |
|
Communication |
Modbus RTU/Hart Protocol options |
Model Selection of chemical resistant Turbine flow meter
Item |
Code |
Description |
General |
SLW |
Silver Liquid turbine flow meter |
Nominal Diameter |
DN15-65 |
DN16-65 |
Type |
N |
Without display, pulse output, 24VDC power supply |
A |
Without display ,4-20mA output, 24VDC power supply |
|
B |
With display, Battery powered, without output |
|
C |
With display,4-20mA output, 24VDC power supply |
|
C3 |
With display, Pulse output, 24VDC power supply |
|
C2 |
With display,4-20mA output and Hart, 24VDC power supply |
|
C1 |
With display,4-20mA output and RS485, 24VDC power supply |
|
Cx |
Customized |
|
Accuracy |
10 |
±1.0% of reading (DN4-DN10,DN125-DN200) |
05 |
±0.5% of reading (In line type,DN15-DN100) |
|
S |
Customized |
|
Flow Range |
S |
Standard (refer to table 2) |
E |
Extended (refer to table 2) |
|
Housing Material |
PE |
PE |
Rotor Material |
PE |
PE |
Explosion Proof |
N |
Non explosion proof |
Pressure rating |
N |
Standard 1.6Mpa |
Temperature |
T1 |
-20 ~80℃ |
Installation |
FL |
Flange connection |
Addition option |
H |
With Hausman Connector |
Sample: SLW-25/C/05/S/PE/PE/N/T1/FL
Liquid turbine flow meter, DN25, With display,4-20mA output, 24VDC power supply, accuracy 0.5%,standard flow range 1-10m3/h, PE material, non explosion proof,1.6Mpa,temperature:-20 ~80℃,flange connection.