Turbine Flow meter for corrosive liquid
Related Products
Chemical flow meters are intended to measure non-corrosive or corrosive liquid and gas, for example pesticides, detergents, acid, solvents and so on. These instrumentations are sometimes needed to be operated in harsh environment.
Why Nitric acid level measurement is a tough job? Nitric acid (HNO3) is a strong acid with strong oxidizing and corrosive properties. The mixture of concentrated nitric acid and concentrated sulfuric ...
1/2 inch turbine flow sensor, DN15, standard flow 10-100 LPM or 400-8000 LPH3/4inch corrosive liquid flow meter, NB20, standard flow 3.5-35 gpm, or 16-318 ft3/h1” chemical resistant flow meter, DN25,1-10 m3/h or 8.3-166 L/min1 1/4” TUF flow meter , DN32, flow range: 0.4-4 m3/h or 3.5 -66 GPM1 1/2 inch turbine flow sensor, DN40, 2-20 m3/h or 1-20 m3/h2” turbine flow meter , DN50, flow range 17-176 GPM, 33-333 m3/h2 1/2 turbine flow transmitter, NB65, flow range 1.94 ~19 .4L/s or 141 -2472 ft3/h
Manufacture Standard |
Turbine flow meter (JB/T9246-1999) |
|
Medium |
Low viscosity(≤5×10-6m2/ s) liquid, no impurities |
|
Flange Standard |
DIN |
|
Thread Standard |
Flange |
|
Accuracy |
1.0%,0.5% |
|
Turn Down Ratio |
1:10-1:20 |
|
Calibration |
Methods |
Master meter calibration |
Static weigh mass flow calibration |
||
Environment |
Environment temperature: 20℃ |
|
Relative Humidity :65% |
||
Working Condition |
Medium temperature |
T1: -20 ~80℃ |
Environment temperature |
-20 ~60℃ |
|
Relative Humidity |
5%-90% |
|
Atmospheric pressure |
86Kpa-106Kpa |
|
Enclosure Protection |
SLW-N:IP60; others IP65 |
|
Transmission Distance |
No more than 1000 m |
|
Material |
Housing: PE Bearings and Shaft: PE Rotor:PE |
|
Consumption |
< 1W |
|
Communication |
Modbus RTU/Hart Protocol options |
Model Selection of chemical resistant Turbine flow meter
Item |
Code |
Description |
General |
SLW |
Silver Liquid turbine flow meter |
Nominal Diameter |
DN15-65 |
DN16-65 |
Type |
N |
Without display, pulse output, 24VDC power supply |
A |
Without display ,4-20mA output, 24VDC power supply |
|
B |
With display, Battery powered, without output |
|
C |
With display,4-20mA output, 24VDC power supply |
|
C3 |
With display, Pulse output, 24VDC power supply |
|
C2 |
With display,4-20mA output and Hart, 24VDC power supply |
|
C1 |
With display,4-20mA output and RS485, 24VDC power supply |
|
Cx |
Customized |
|
Accuracy |
10 |
±1.0% of reading (DN4-DN10,DN125-DN200) |
05 |
±0.5% of reading (In line type,DN15-DN100) |
|
S |
Customized |
|
Flow Range |
S |
Standard (refer to table 2) |
E |
Extended (refer to table 2) |
|
Housing Material |
PE |
PE |
Rotor Material |
PE |
PE |
Explosion Proof |
N |
Non explosion proof |
Pressure rating |
N |
Standard 1.6Mpa |
Temperature |
T1 |
-20 ~80℃ |
Installation |
FL |
Flange connection |
Addition option |
H |
With Hausman Connector |
Sample: SLW-25/C/05/S/PE/PE/N/T1/FL
Liquid turbine flow meter, DN25, With display,4-20mA output, 24VDC power supply, accuracy 0.5%,standard flow range 1-10m3/h, PE material, non explosion proof,1.6Mpa,temperature:-20 ~80℃,flange connection.
we will contact you within 24 hours.