What is Orifice Plate Flow Meter?An orifice plate flow meter is a devicewith a hole in it, the function of which is for ...
Wedge Flow meter overviewA wedge flow meter is a flow measuringdevice or instrument that calculated the flow rate of liq...
Multi hole balanced flow sensor is actually a flow rectifier, can effectively eliminate swirl and distorted velocity distribution improvements, the ideal state of the flow field approximation, the conventional measure for level 0.5, high accuracy measurement for level 0.2.
Multi hole balanced flow sensor is a with multi holes, select the appropriate equivalent diameter ratio, favor the lower limit of the flow also give consideration to the upper limit flow ,making the conventional measure flow turndown ratio of 10:1, if appropriate parameter selection, turndown ratio can be raised to 20: 1 ~ 30:1
Balanced flow sensor can adjust the flow stable and pressure recovery 2 times faster than conventional orifice throttling device, greatly reducing the requirement for straight pipe. Lower straight pipe section can be as small in most cases 0.5D ~ 2D, a balanced flow meter can save a lot of straight pipe sections, in particular pipe with expensive special materials.
Balanced flow meter multi hole symmetrical design reduces the formation of vortices and turbulence of friction, reducing the kinetic energy loss. In the same working condition without reducing the differential pressure, balance flow meter can reduce 1/2~1/3 permanent pressure loss comparing with the conventional throttle device to reduce the cost.
Balanced flow sensor of SILVER AUTOMATION INSTRUMENTS is with stable flow to improved repeatability up 0.1%.
Balanced flow meter multiple circulation holes dispersed by force, no acute wear, its β value of long-term unchanged to maintain stability, the whole instrument with no moving parts , extend the service life of 5 to 10 times faster than conventional throttling device .
Porous symmetrical balanced design reduces the formation of vortex turbulent shear force fit , thereby greatly reducing the formation of dead zone residence , dirty media to ensure a plurality of holes pass , reducing the chance of fluid holes are blocked .
Working temperature and pressure of balanced flow sensor is decided by pipe and flange material, it can reach to 800 ℃, 42MPa or higher temperature, pressure medium. Suitable for cryogenic fluid LNG \ liquid air , liquid ammonia , liquid oxygen, liquid fluoride , liquefied ethylene, liquid hydrogen , chlorine , etc., can effectively prevent vaporization , measuring good effect.
Item |
Code |
Description |
Product |
SD14 |
Balanced Flow Meter |
Mounting |
W F H FF FT FS FV J S Z |
Wafer type Flange type Direct Welding Flange Taping Special Material of Double flange Anti-corrosion Type Heating Jacket Square TubeType Integral Installation Type Others |
Size |
xxx |
For example, 150 stands for DN150 |
Housing Material |
A B C D E Z |
Carbon Steel 304 Stainless steel 316L stainless steel High temperature alloy PTFE lined carbon steel Others |
Sensor Material |
A B C D E Z |
304 Stainless steel 316L stainless steel HC-276 Monel 400 Inconel635 Others |
Pressure Rating |
1 2 3 4 5 6 7 8 9 A1 A2 A3 A4 A5 Z |
PN0.6 PN1.0 PN1.6 PN2.5 PN4 PN6.4 PN10 PN16 PN25 CL150(ANSI/ASME) CL300(ANSI/ASME) CL600(ANSI/ASME) CL900(ANSI/ASME) CL1500(ANSI/ASME) Others |
Tapping Type |
A B C D Z |
NPT (Thread type) PSW (Direct Welding) 1” Flange 2” Flange Others |
Accessories |
P E F G |
Differential Pressure Transmitter Companion Flanges (bolts, nuts, gasket included) Siphon 3-way manifold |
Note:
1. Wafer type with NPT thread tapping: DN10~DN40, C=1/4, DN50~DN3000,C=1/2”
2. Only Flange tapping available for heating jack type, DN40~DN50 1” Flange, DN80~DN350 2” flange.
we will contact you within 24 hours.